欢迎来到科创生物!  股权交易代码:900416

15850060768

 全部分类 

当前位置: 首页 > 产品中心 > 抗体 > 一抗 > 其他相关抗体
  • EventCoat Goat Anti-Mouse IgG Coated

  • 产品货号:CP002
  • 产品品牌:R&D产品规格:1Pack
  • 收藏
货号 产品规格 计量单位 目录价(RMB) 会员价(RMB) 货期 数量 加入购物车...
CP002 1Pack ¥5769.00元 ¥5769.00元 3-5周
- +
立即购买
注册成为会员,并按会员价充值,可额外获赠5%金额。

产品介绍

MSDS与安全信息

质检证书(COA)

相关产品

ORDERING INFORMATION & SPECIFICATIONS:Coating Antibody: Goat Anti-Mouse IgG Specificity: mouse IgG Fc Region Coating Volume: 100 μL/well Blocking Volume: 300 μL/wellSuggested Mouse IgG Concentration: 1.0-5.0 μg/mL (0.1-0.5 μg/well) STABILITY AND STORAGEINTENDED USE :EvenCoat™ goat anti-mouse IgG microplates are clear, pre-blocked 96-well polystyrene microplates coated with goat-derived antibody specific for the Fc region of mouse IgG. These plates may be used as a solid support for most sandwich ELISAs utilizing a mouse IgG capture antibody and a non-mouse IgG detection antibody. Other applications include competitive ELISA, IgG isotyping, and hybridoma screening/selection. An example protocol for a sandwich ELISA is described below.RELATED PRODUCTS:• DuoSet® ELISA Development Kits (See website). • Matched Antibody Pairs (See website). • Streptavidin-HRP (R&D Systems®, Catalog # DY998). • Substrate Solution (R&D Systems®, Catalog # DY999). • Wash Buffer (R&D Systems®, Catalog # WA126).PROTOCOL FOR SANDWICH ELISA USING DUOSET DEVELOPMENT KITS:Note: EvenCoat™ Microplates may be used with most DuoSet® ELISA Development Kits. Reconstitute DuoSet® reagents, prepare working concentrations, and prepare ancillary reagents (except Block Buffer, which is not required when using EvenCoat™ Microplates) as instructed in the DuoSet® product insert1. Add 100 μL of diluted capture antibody to each well. Cover with an adhesive strip and incubate for 1 hour at room temperature. 2. Aspirate each well and wash with Wash Buffer, repeating the process two times for a total of three washes. Wash by filling each well with Wash Buffer (400 μL) using a squirt bottle, multi-channel pipette, manifold dispenser or autowasher. Complete removal of liquid at each step is essential for good performance. After the last wash, remove any remaining Wash Buffer by aspirating or decanting. Invert the plate and blot it against clean paper towels. 3. Add 100 μL of sample or standard in reagent diluent (or an appropriate diluent) to each well. Cover with an adhesive strip and incubate for 1.5-2.0 hours at room temperature. 4. Repeat the aspiration/wash as in step 2. 5. Add 100 μL of detection antibody, diluted in reagent diluent, to each well. Cover with an adhesive strip and incubate for 1.5-2.0 hours at room temperature. 6. Repeat the aspiration/wash as in step 2. 7. Add 100 μL of the working dilution of Streptavidin-HRP to each well. Cover with an adhesive strip and incubate for 20 minutes at room temperature. Note: Streptavidin-HRP concentration may have to be adjusted for optimal signal generation. 8. Repeat the aspiration/wash as in step 2. 9. Add 100 μL of Substrate Solution to each well. Incubate for 20 minutes at room temperature. Protect from light. 10. Add 50 μL of Stop Solution to each well. Gently tap the plate to ensure thorough mixing. 11. Determine the optical density of each well immediately, using a microplate reader set to 450 nm. If wavelength correction is available, set to 540 nm or 570 nm. If wavelength correction is not available, subtract readings at 540 nm or 570 nm from the readings at 450 nm. This subtraction will correct for optical imperfections in the plate. Readings made directly at 450 nm without correction may be higher and less accurate.
ICP备案证书号:苏ICP备13017990号-1 © 2005-2022 苏州科创生物技术有限公司 版权所有,并保留所有权利。